Details
⚡ Medical Device — Class II

Positive Pressure Therapy for
Obstructive Sleep Apnea

The R20 and R200 deliver clinically reliable positive airway pressure therapy for adult patients with obstructive sleep apnea syndrome. Suitable for both home and hospital environments, with intelligent humidification and real-time monitoring via Bluetooth.

⚠  For patients ≥ 30 kg · Use under professional medical guidance · Not for self-diagnosis
Select Model
R20 Features

3.5″ LCD Colour Touch Screen

Full-colour display for intuitive therapy management and real-time data at a glance.

CPAP & APAP Modes

Fixed or auto-adjusting pressure for tailored therapy that adapts to breathing patterns.

8-Event Detection Engine

Accurately identifies OA, CA, H, RERA, Snoring, PB, LL, and central respiratory events.

Intelligent Humidification

Preheat technology with 5 humidity levels and noise control for quiet, comfortable therapy.

Bluetooth Connectivity

Pairs with LEPU SpO₂ and ECG sensors for continuous multi-parameter monitoring.

8 GB Storage + Wi-Fi

Stores detailed session data for clinical review and remote therapy management.

R200 Features

3.5″ LCD Colour Touch Screen

Vibrant full-colour touchscreen for effortless control and real-time therapy data.

5 NIV Modes: CPAP, APAP, S, T, S/T

Advanced bilevel modes for patients requiring two-level pressure support therapy.

8-Event Detection Engine

Accurately identifies OA, CA, H, RERA, Snoring, PB, LL, and central respiratory events.

Intelligent Humidification

Preheat technology with 5 humidity levels and noise control for quiet, comfortable therapy.

Bluetooth Connectivity

Pairs with LEPU SpO₂ and ECG sensors for continuous multi-parameter monitoring.

Extended Pressure: 4–25 cmH₂O

Higher maximum pressure vs R20's 4–20 for complex cases needing stronger airway support.

Blood Oxygen Monitoring

SpO₂ Levels — Before & After Treatment

LEPU ventilators help restore blood oxygen saturation toward healthy levels during therapy.

Normal Range (Post-Treatment Goal)95% – 100%
Mild Hypoxia90% – 94%
Severe Hypoxia (Requires Urgent Care)Below 90%
Normal / Treated
Mild Hypoxia
Severe Hypoxia
Product Details
01 Key Features — Both Models
  • Touch Display: 3.5-inch full-colour LCD touchscreen for intuitive, at-a-glance therapy management.
  • Event Detection: 8 respiratory events — OA (Obstructive Apnea), CA (Central Apnea), H (Hypopnea), RERA, Snoring, PB (Periodic Breathing), LL (Large Leak), and central respiratory events.
  • Smart Humidification: Pre-heat technology, 5 humidity levels, and noise-reduction algorithm for all-night comfort.
  • Bluetooth + Wi-Fi: Connect LEPU SpO₂ and ECG accessories for real-time multi-parameter monitoring and remote data access.
  • Ramp Function: Gradual pressure increase (0–60 min) to help patients fall asleep before full therapy begins.
  • 8 GB Storage: Onboard memory for detailed session history and clinician review.
  • 5-Year Service Life: Built for reliable long-term use in home and clinical settings.
  • R200 Exclusive: S, T, and S/T bilevel modes plus higher maximum pressure (25 cmH₂O) for complex cases.
02 Technical Specifications
Screen Size3.5 inch (Both)
R20 Pressure Range4 – 20 cmH₂O
R200 Pressure Range4 – 25 cmH₂O
Pressure Accuracy± 0.5 cmH₂O
Ramp Time0 – 60 minutes
Humidification1 – 5 Levels
Data Storage8 GB
BluetoothSupported
Wi-FiSupported
Service Life5 Years
Device Weight1.6 KG
Heating TubeOptional
03 Usage & Medical Information
Indications for Use

For adult obstructive sleep apnea syndrome in spontaneously breathing patients. Suitable for home and clinical environments. Patient must weigh ≥ 30 kg (66 lbs).

Setup & Daily Use

Attach the prescribed mask to device tubing. Set mode and pressure as directed by your clinician. Use nightly for at least 4 hours. Clean mask and humidifier chamber regularly per the device manual.

Monitoring & Follow-up

Connect the LEPU SpO₂ sensor via Bluetooth for real-time oxygen tracking. Session data (8 GB) can be exported for clinician review. Regular follow-up is recommended to optimise settings.

Must be used under guidance of a qualified medical professional. Do not adjust pressure without consulting your doctor. Not for emergency respiratory support.
Model Comparison
Parameter R20 R200
Therapy Modes CPAP, APAP CPAP, APAP, S, T, S/T+3 Modes
Screen Size 3.5 inch 3.5 inch
Pressure Range 4 – 20 cmH₂O 4 – 25 cmH₂O+5 cmH₂O
Pressure Accuracy 0.5 cmH₂O 0.5 cmH₂O
Ramp Time 0 – 60 min 0 – 60 min
Humidification 1 – 5 Levels 1 – 5 Levels
Data Storage 8 GB 8 GB
Bluetooth ✓ Supported ✓ Supported
Wi-Fi ✓ Supported ✓ Supported
Service Life 5 Years 5 Years
Weight 1.6 KG 1.6 KG
Heating Tube Optional Optional
Best For Standard OSA therapy Complex / bilevel therapy needs